Item 1. Business
Item
1. Business.
Overview
We
are a medical device company focusing on the development and commercialization of products for the treatment of carotid artery disease
and other vascular disease, including our proprietary CGuard™ stent platform. A stent is an expandable scaffold-like device, usually
constructed of a metallic material, that is inserted into the lumen of an artery to create patency and improved blood flow. A sleeve
of MicroNet™ mesh is attached over a stent to provide embolic protection both during and after stenting procedures.
Our
CGuard™ carotid embolic prevention system (“CGuard EPS”) combines MicroNet and a unique self-expandable nitinol stent
in a single device for use in carotid artery revascularization. Our CGuard EPS originally received CE mark approval under Medical Device
Directive 93/42/EEC (“MDD”) in the European Union (“EU”) in March 2013 and was fully launched in Europe in September
2015. Subsequently, we launched CGuard EPS in over 30 countries and on February 3, 2021, we executed a distribution agreement with Chinese
partners for the purpose of expanding our presence in the Asian markets. In January 2024, we received CE mark recertification under the
EU’s Medical Device Regulation regulatory framework.
On
September 8, 2020, we received approval from the U.S. Food and Drug Administration (“FDA”) of our Investigation Device Exemption
(“IDE”), thereby allowing us to proceed with a pivotal study of our CGuard™ Carotid Stent System, C-GUARDIANS, for
prevention of stroke in patients in the United States. C-GUARDIANS is a prospective, multicenter, single-arm, pivotal study to evaluate
the safety and efficacy of the CGuard™ Carotid Stent System when used to treat symptomatic and asymptomatic carotid artery stenosis
in patients undergoing carotid artery stenting (“CAS”). The study, which completed enrollment in June 2023, enrolled 316
patients across 24 trial sites in the U.S. and Europe and from April 2023 included deployment of the CGuard stent using CGuard Prime,
our next generation CAS stent platform.
The
primary endpoint was a composite of: (1) incidence of major adverse events including Death (all-cause mortality), any Stroke, and Myocardial
Infarction (DSMI) through 30-days post index procedure, or (2) ipsilateral stroke from day 31 to day 365 post-procedure. All events were
adjudicated by an independent clinical events committee. The composite index was compared to a performance goal based on the observed
rate of the two components of the primary endpoint from previous pivotal stent trials which are considered industry standard. The performance
goal was considered met if the upper bound of the two-sided 95% confidence interval calculated from the observed primary endpoint rate
is < 11.6% and the p-value is less than 0.025.
In
November 2023, we announced positive 30-day follow up results from the C-GUARDIANS trial in which stenting with the CGuard Carotid Stent
System in patients with carotid artery stenosis and at high risk for carotid endarterectomy had a DSMI rate of 0.95%, measured from the
date of the procedure through 30 days follow-up post-procedure. In May 2024, we announced positive one-year follow up results from the
C-GUARDIANS trial, with a rate of 30-day DSMI and ipsilateral stroke between 31 and 365 days of 1.95%.
These
data were used to support the premarket approval (“PMA”) submission in September 2024 with a view to potential FDA approval of the CGuard
Prime carotid stent system in the first half of 2025.
In
October 2024, the FDA approved the Company’s IDE to initiate the CGUARDIANS II pivotal study of its CGuard Prime 80cm Carotid Stent
System during transcarotid revascularization (TCAR) procedures.
In
October 2023, the Centers for Medicare and Medicaid Service (“CMS”) issued its final National Coverage Determination (“NCD”),
expanding coverage for both CAS and TCAR to include both asymptomatic and standard risk patients, significantly expanding and supporting
the future growth of the U.S. CAS addressable market.
We
continue to invest in current and future potential new indications, products and manufacturing enhancements for CGuard that are expected
to reduce cost of goods and/or provide the best-in-class performing delivery systems, such as CGuard Prime. In furtherance of our strategy
that focuses on establishing the CGuard Carotid Stent System as a viable alternative to vascular surgery, we are developing a new transcarotid
artery revascularization (TCAR) system, SwitchGuard™ neuroprotection system (“SwitchGuard NPS”), for transcarotid access
and neuro protection. In addition, we intend to explore new indications for CGuard to leverage the advantages of stent design and mesh
protection, well suited in labels such as acute stroke with tandem lesions.
5
We
consider our current addressable market for our CGuard Carotid Stent System and SwitchGuard NPS to be both symptomatic and asymptomatic
individuals with diagnosed high-grade carotid artery stenosis for whom intervention is preferable to medical (drug) therapy. This group
includes not only carotid artery stenting patients but also individuals undergoing carotid endarterectomy, as the two approaches compete
for the same patient population. Assuming full penetration of the intervention caseload by CGuard, we estimate that the addressable market
for CGuard Carotid Stent System and SwitchGuard NPS is approximately $1.3 billion (source: Health Research International Personal Medical
Systems, Inc. September 13, 2021 Results of Update Report on Global Carotid Stenting Procedures and Markets by Major Geography and Addressable
Markets and internal estimates). According to this same report and internal estimates, assuming full penetration of treatment for all
individuals diagnosed with high-grade carotid artery stenosis, we estimate the total available market for CGuard Carotid Stent System
and SwitchGuard NPS to be approximately $9.3 billion, which may grow over time if expanded treatment options such as CGuard Carotid Stent
System and SwitchGuard NPS lead to increased patient screening for carotid artery disease.
We
were organized in the State of Delaware on February 29, 2008. In October 2024, we established our global headquarters in Miami, Florida
to support the anticipated U.S. launch and commercialization of the CGuard Prime carotid stent system.
Private
Placement
On
May 12, 2023, we entered into a securities purchase agreement (the “Purchase Agreement”) pursuant to which we agreed to sell
and issue in a private placement (the “Private Placement Offering”) an aggregate of 10,266,270 shares (the “Private
Placement Shares”) of our common stock, pre-funded warrants (the “Pre-Funded Warrants”) to purchase up to 15,561,894
shares of common stock and warrants to purchase up to an aggregate of 51,656,328 shares of common stock, consisting of Series H warrants
to purchase up to 12,914,086 shares of common stock (the “Series H Warrants”), Series I warrants to purchase up to 12,914,078
shares of common stock (the “Series I Warrants”), Series J warrants to purchase up to 12,914,086 shares of Common Stock (the
“Series J Warrants”) and Series K warrants to purchase up to 12,914,086 shares of common stock (the “Series K Warrants”
and together with the Series H Warrants, Series I Warrants and Series J Warrants, the “Warrants”), at an offering price of
$1.6327 per Private Placement Share and associated Warrants and an offering price of $1.6326 per Pre-Funded Warrant and associated Warrants.
The
Pre-Funded Warrants will be immediately exercisable at an exercise price of $0.0001 per share and will not expire until exercised in
full. The Warrants will be immediately exercisable upon issuance at an exercise price of $1.3827 per share, subject to adjustment as
set forth therein. The Warrants have a term of the earlier of (i) five years from the date of issuance and (ii) (A) in the case of the
Series H Warrants, 20 trading days following the Company’s public release of primary and secondary end points related to one year
follow up study results from the Company’s C-GUARDIANS pivotal trial, (B) in the case of the Series I Warrants, 20 trading days
following the Company’s announcement of receipt of Premarket Approval from the Food and Drug Administration (“FDA”)
for the CGuard Prime Carotid Stent System (135 cm), (C) in the case of the Series J Warrants, 20 trading days following the Company’s
announcement of receipt of FDA approval for the SwitchGuard and CGuard Prime 80 and (D) in the case on the Series K Warrants, 20 trading
days following the end of the fourth fiscal quarter after the fiscal quarter in which the first commercial sales of the CGuard Carotid
Stent System in the United States begins.
The
Warrants may be exercised on a cashless basis if there is no effective registration statement registering the shares underlying the Warrants.
On May 23, 2023, we filed registration statement on Form S-3 (File No. 333-272149) registering the shares underlying the Warrants, which
was declared effective by the Securities and Exchange Commission on June 2, 2023. Under the terms of the Pre-Funded Warrants and Warrants,
certain of the selling stockholders may not exercise the Pre-Funded Warrants or Warrants to the extent such exercise would cause such
selling stockholder, together with its affiliates and attribution parties, to beneficially own a number of shares of common stock which
would exceed 4.99% or 9.99% of our then outstanding common stock following such exercise, excluding for purposes of such determination
common stock issuable upon exercise of the Pre-Funded Warrants or Warrants which have not been exercised. The Warrants may be exercised
into pre-funded warrants if the selling stockholder is unable to exercise the Warrant due to the foregoing beneficial ownership limitation
or at the selling shareholder’s election.
Following
the announcement of the one year follow up study results from the Company’s C-GUARDIANS trial, Series H Warrants to purchase 12,914,086
shares of common stock were exercised in full into 292,996 of shares of common stock and pre-funded warrants to purchase 12,621,090 shares
of common stock. The net proceeds to the Company from the exercise of the Series H Warrants were $16.9 million, after deducting placement
agent fees. The Series H warrants, each exercisable at $1.3827 per common share and $1.3826 per pre-funded warrant, were issued as part
of the private placement financing that the Company consummated on May 15, 2023.
6
Our
Industry
Carotid
Carotid
arteries are located on each side of the neck and provide the primary blood supply to the brain. Carotid artery disease, also called
carotid artery stenosis, is a type of atherosclerosis (hardening of the arteries) that is one of the major risk factors for ischemic
stroke. In carotid artery disease, plaque accumulates in the artery walls, narrowing the artery and disrupting the blood supply to the
brain. This disruption in blood supply, together with plaque debris breaking off the artery walls and traveling to the brain, are significant
causes of stroke. According to the World Health Organization (https://www.who.int/cardiovascular_diseases/resources/atlas/en/) every
year, 15 million people worldwide suffer a stroke, and nearly six million die and another five million are left permanently disabled.
According to the same source, stroke is the second leading cause of disability, after dementia.
In
2022, three million people between the age of 50 and 89 years old were estimated to be diagnosed with high grade carotid artery disease,
of which, approximately 394,000 of those required intervention (according to the Health Research International Personal Medical Systems,
Inc. September 13, 2021 Results of Update Report on Global Carotid Stenting Procedures and Markets by Major Geography and Addressable
Markets). There are three current interventional treatments used for carotid artery disease. The first is a carotid endarterectomy, where
a surgeon accesses the blocked carotid artery though an incision in the neck, and then surgically removes the plaque. The second is transcarotid
artery revascularization (TCAR) where a surgeon accesses the blocked carotid artery though an incision in the neck, and then places a
stent to open the artery and prevent embolization while combining high-rate blood flow reversal to protect the brain. The third is carotid
artery stenting (CAS), which is a minimally invasive endovascular treatment for using stents and carotid embolic protection systems to
protect against plaque and debris traveling downstream, blocking off the vessel and disrupting blood flow. We believe that the availability
of less invasive treatment options like TCAR and CAS should increase the number of patients being treated since they avoid the need for
complex surgery.
Our
Products
MicroNet
Mesh Platform Technology
MicroNet
is our proprietary knitted mesh which wraps around a stent to protect patients from plaque prolapse and embolization upon deployment.
MicroNet is made of a single fiber from a biocompatible polymer widely used in medical implants. The size, or aperture, of the current
MicroNet ‘pore’ is only 150-180 microns, designed to maximize protection against the potentially dangerous plaque and thrombus.
The MicroNet mesh is the core technology around which we have developed products for specific applications.
CGuard
– Carotid Artery Applications
Our
CGuard EPS combines our MicroNet mesh and a self-expandable nitinol stent (a stent that expands without balloon dilation pressure or
need of an inflation balloon) in a single device for use in carotid artery applications. MicroNet is placed over and attached to the
outside of an open cell nitinol stent, forming a highly flexible implant that conforms to the carotid anatomy designed to trap debris
and emboli that can dislodge from the diseased carotid artery and potentially travel to the brain and cause a stroke. This danger is
one of the greatest limitations of carotid artery stenting with conventional carotid stents.
We
believe that our CGuard EPS design provides advantages over existing therapies in treating carotid artery stenosis, such as conventional
carotid stenting and surgical endarterectomy, given the superior embolic protection characteristics provided by the MicroNet. We believe
the MicroNet will provide acute embolic protection at the time of the procedure, but more importantly, will provide post-procedure protection
against embolic dislodgement. It is in this post-procedure time frame that embolization is the source of post-procedural strokes in the
brain. Schofer, et al. (“Late cerebral embolization after emboli-protected carotid artery stenting assessed by sequential diffusion-weighted
magnetic resonance imaging,” Journal of American College of Cardiology Cardiovascular Interventions , Volume 1, 2008) have
shown that the majority of the incidents of embolic showers associated with carotid stenting occur post-procedure.
Our
CGuard EPS originally received CE mark approval in the EU in March 2013 and was fully launched in Europe in September 2015. Subsequently,
we launched CGuard EPS in 30 plus countries and on February 3, 2021, we executed a distribution agreement with Chinese partners for the
purpose of expanding our presence in China.
On
September 8, 2020, we received approval from the FDA of our IDE, thereby allowing us to proceed with a pivotal study of our CGuard™
Carotid Stent System, C-GUARDIANS, for prevention of stroke in patients in the United States. C-GUARDIANS is a prospective, multicenter,
single-arm, pivotal study to evaluate the safety and efficacy of the CGuard™ Carotid Stent System when used to treat symptomatic
and asymptomatic carotid artery stenosis in patients undergoing carotid artery stenting. The study, which completed enrollment in June
2023, enrolled 316 patients across 24 trial sites in the U.S. and Europe and from April 2023 included deployment of the CGuard stent
using CGuard Prime, our next generation CAS stent platform.
7
The
primary endpoint is a composite of: (1) incidence of major adverse events including Death (all-cause mortality), any Stroke, and Myocardial
Infarction (DSMI) through 30-days post index procedure, or (2) ipsilateral stroke from day 31 to day 365 post-procedure. All events are
adjudicated by an independent clinical events committee. The composite endpoint will be compared to a performance goal based on the observed
rate of the two components of the primary endpoint from previous pivotal stent trials which are considered industry standard. The performance
goal will be considered met if the upper bound of the two-sided 95% confidence interval calculated from the observed primary endpoint
rate is < 11.6% and the p-value is less than 0.025.
In
November 2023, we announced positive 30-day follow up results from the C-GUARDIANS trial in which stenting with the CGuard Carotid Stent
System in patients with carotid artery stenosis and at high risk for carotid endarterectomy had a DSMI rate of 0.95%, measured from the
date of the procedure through 30 days follow-up post-procedure. In May 2024, we announced positive one-year follow up results from the
C-GUARDIANS trial, with a rate of 30-day DSMI and Ipsilateral stroke between 31 and 365 days of 1.95%. These data were used to support
the premarket approval, or PMA, submission in September 2024 with a view to potential FDA approval of the CGuard Prime carotid stent
system in the first half of 2025.
CGuard
Prime Stent System
The
CGuard Prime stent system is a mesh-covered self-expanding carotid stent that is loaded into a rapid exchange (Rx) delivery system that
is subject to regulatory approval.
The
CGuard Prime Carotid Stent is a self-expanding nitinol stent covered with a MicroNet bio-stable sleeve woven from a single strand of
23 μm Polyethylene Terephthalate (PET). The MicroNet sleeve is designed to trap and seal thrombus and plaque against the vessel wall,
providing continuous embolic prevention. The CGuard Prime Carotid Stent is available in diameters ranging from 6mm to 10mm and in lengths
of 20, 30, 40 and 60mm. The CGuard Prime delivery system is a rapid exchange (Rx), delivery system with a 6Fr profile that can accommodate
all stent sizes from 6mm to 10mm. In the U.S., we are currently seeking approval only for stent sizes in 8, 9 and 10 mm in diameter with
lengths of 30 and 40 mm.
CGuard
Prime 135 cm advances the first generation CGuard transfemoral delivery system with a new handle design for ease of deployment and a
new catheter design for more flexible navigation of tortuous anatomy. The CGuard Prime product was used in 32 patients out of 315 patients
in the CGuardians study, since April 2023. In October 2024, the FDA approved the Company’s IDE to initiate the CGUARDIANS II study
of its CGuard Prime 80cm Carotid Stent System for use in the indication of transcarotid revascularization (TCAR) procedures.
The
CGuard Prime Technical Documentation is currently under Notified Body review for EU MDR certification.
SwitchGuard
NPS
SwitchGuard
NPS is a Class IIa neuroprotection system (NPS) that we have developed and that is subject to regulatory approval, composed of medical
grade tubing with male Luer lock connectors at each end and an in-line 200-micron blood filter. When connected to the included arterial
and venous sheaths, the system is intended as an external arterial-venous (A-V) shunt, allowing arterial blood to flow into the venous
system, while filtering particulate before returning blood to the patient on the venous side.
SwitchGuard
is being developed to answer a need of flow reversal for cerebral protection in carotid interventions since symptomatic distal embolization,
caused by the release of material (thrombotic, necrotic, or atherosclerotic) from the site of the lesion during the intervention, is
the most frequent and important complication of CAS. Reversing blood flow has been shown to reduce stroke risk during carotid artery
procedures.
We
submitted an IDE to the FDA for the C-GUARDIANS III clinical trial in December 2024, which, if approved, would allow us to initiate a
clinical trial to support the clearance of the SwitchGuard NPS coupled with CGuard Prime.
8
Acute
Stroke with Tandem Lesions
It
is estimated that 20-30% of acute ischemic strokes are caused by large vessel occlusion involve tandem lesions- high grade stenosis/occlusion
of the internal carotid artery plus thrombotic occlusion of an intracranial vessel. Currently there is no indicated use of CAS for these
lesions during stroke treatment when the placement of an embolic protection device is not possible. We believe CGuard Prime is optimally
suited for intervention in this acute setting by its design (flexible / low metal structure) as well as MicroNet mesh offering embolic
protection both during and post procedure. Our goal is to develop CGuard Prime to mitigate strokes in this acute setting.
In
November 2023, we announced a strategic agreement with Jacobs Institute to execute an early feasibility study of CGuard Prime for the
treatment of acute stroke patients with tandem lesions. The study is expected to enroll 15 acute stroke patients across three U.S. sites
to explore the safety and feasibility of using CGuard Prime in this setting.
MGuard
Prime
We
historically developed and sold the MGuard Prime embolic protection system (“MGuard Prime EPS”) which was marketed for use
in patients with acute coronary syndromes, notably acute myocardial infarction (heart attack) and saphenous vein graft coronary interventions.
Over the past years there has been a shift in industry preferences towards drug eluting stents. As a result of declining sales and utilization
of the MGuard Prime EPS, which was largely driven by the predominant industry preferences favoring drug-eluting stents, during the second
quarter of 2022 we ceased sales of MGuard Prime EPS following a phase out period.
Completed
Clinical Trials for CGuard EPS
CARENET
The
CARENET trial was the first multi-center study of CGuard EPS following the receipt of CE mark of this device in March 2013. The CARENET
trial was designed to evaluate feasibility and safety of CGuard EPS in treatment of carotid lesions in consecutive patients suitable
for CASin a multi-operator, real-life setting. The acute, 30-day, magnetic resonance imaging (“MRI”), ultrasound and six-month
clinical event results were presented at the LINC conference in Leipzig, Germany in February, 2015. In the third quarter of 2015, the
results of the CGuard CARENET trial were published in the Journal of the American College of Cardiology. In November 2015, positive twelve-month
follow-up data from the CGuard CARENET trial was presented at the 42nd Annual Symposium on Vascular and Endovascular Issues, documenting
the benefits of the CGuard MicroNet technology as well as the patency benefits (maintaining the artery open) of the internal and external
carotid arteries at twelve months. In September 2022, the results of the CGuard CARENET trial five year follow up were published in the
Journal of the American College of Cardiology: Cardiovascular Interventions Vol. 15, No 18, 2022 September 26, 2022:1883-1891. There
was no ipsilateral stroke or ipsilateral stroke-related death which occurred throughout the five years. In addition, no stent restenosis
or external carotid artery occlusion occurred in CARENET by 5 years, indicating normal healing and uncompromised side-branch patency.
MACCE
(myocardial infarction (“MI”), stroke or death) rate was 0.0% at 30 days. At six months, there was one death, which was not
device or procedure-related but did result in a MACCE rate of 3.6% at six months. At twelve months there were two additional deaths,
which were not device or procedure-related resulting in a MACCE rate of 10.7% at one year.
30 days
(n=30)
6 months
(n=28)
12 months
(n=28)
MACCE (MI, stroke, death)
(0) 0.0 %
(1) 3.6 %
(3) 10.7 %
MI
(0) 0.0 %
(0) 0.0 %
(0) 0.0 %
stroke
(0) 0.0 %
(0) 0.0 %
(0) 0.0 %
death
(0) 0.0 %
(1) 3.6 %
(3) 10.7 %
9
CAS
carries the risk of cerebral embolization during and following the procedure, leading to life-threatening complications, mainly cerebral
ischemic events. Diffusion-weighted magnetic resonance imaging (DW-MRI) is a sensitive tool used to identify cerebral emboli during CAS
by measuring “lesions” within the brain which are areas that are ischemic and do not receive oxygenated blood due to cerebral
emboli. In the CARENET trial, 37.0% of patients treated with CGuard EPS had new ischemic lesions at 48 hours after the procedure, with
an average volume of 0.039 cm3. Of these lesions, there was only one that remained at 30 days following the procedure and all others
had resolved. Complete details appear in the following table. Where there is a second number shown below after a ± symbol, it
indicates the potential error in the measurement.
48 hours
n=27
30 days
n=26
Subjects with new Acute Ischemic Lesions (“AIL”)
10
1
Incidence of new lesions
37.0 %
4.0 %
Total number new AIL
83
1
Avg. number new AIL per patient
3.19 ± 10.33
0.04 ± 0.20
Average lesion volume (cm 3 )
0.039 ± 0.08
0.08 ± 0.00
Maximum lesion volume (cm 3 )
0.445
0.116
Permanent AIL at 30 days
—
1
The
healing process of the tissue and in-stent restenosis can be measured by a non-invasive form of ultrasound called duplex ultrasound.
This type of ultrasound measures the velocity of the blood that flows within the carotid arteries, which increases exponentially as the
lumen of the internal carotid artery narrows and the percent stenosis increases. One of the measurements is called PSV (peak systolic
volume) and is known to be highly correlated to the degree of in-stent restenosis; PSV values higher than 300 cm/sec are indicative of
>70% stenosis, while PSV values lower than 104 cm/sec are indicative of <30% restenosis and healthy healing. In the CARENET trial,
duplex ultrasound measurements done at 30 days, 6 months and 12 months following the stenting procedure all attest to healthy normal
healing without restenosis concerns, as the PSV values were 60.96 cm/sec ± 22.31, 85.24 cm/sec ± 39.56, and 90.22 cm/sec
± 37.72 respectively. The internal carotid artery was patent in all patients (100%).
The
conclusions of the CARENET trial were:
●
The
CARENET trial demonstrated safety of the CGuard EPS stent, with a 30 day MACCE rate of 0%.
●
Incidence
of new ipsilateral lesions (percent of patients with new lesions on the ipsilateral side (same side where the stent was employed))
at 48 hours was reduced by almost half compared to published data, and volume was reduced almost tenfold.
●
All
but one lesion had resolved completely by 30 days.
●
Twelve-month
data showed no stroke or stroke-related deaths, and no cardiac adverse events.
●
Five-year
data showed no ipsilateral stroke or ipsilateral stroke-related deaths, and no stent restenosis or external carotid artery occlusion
occurred in CARENET by 5 years, indicating normal healing and uncompromised side-branch patency.
●
CGuard
EPS offers enhanced benefits for patients undergoing CAS with unprecedented safety.
10
Physician-Sponsored
Clinical Trials for CGuard—PARADIGM-101 and PARADIGM -500 Studies
PARADIGM-101
( P rospective evaluation of A ll-comer pe R cutaneous c A roti D revascularization
I n symptomatic and increased-risk asymptomatic carotid artery stenosis, using C G uard™ M esh-covered
embolic prevention stent system-101) was an investigator-led, single center study with the objective of evaluating feasibility and outcome
of routine use of CGuard EPS in 101 consecutive unselected all-comer patients referred for carotid revascularization, initiated in 2015.
In May 2016, the 30-day results were presented at the EuroPCR 2016 Late-Breaking Clinical Trial Session in Paris, and in the Journal
of EuroIntervention. In Dec 2020, the 12 month results were presented in the Official Journal of the EuroPCR and the European Association
of Percutaneous Coronary Interventions, EuroIntervention 2020;16:e950-e952. DOI: 10.4244/EIJ-D-19-01014) Key findings from the PARADIGM-101
study and the follow-up data are as follows:
●
CGuard
EPS delivery success was 99.1%. The clinical evaluation also found no device foreshortening or elongation;
●
Angiographic
diameter stenosis or vessel narrowing was reduced from 83±9% to only 6.7±5% (p<0.001);
●
Periprocedural
death/major stroke/ myocardial infarction (“MI”) rates were 0%;
●
Between
30 days and 12 months, there were no strokes or stroke-related deaths. There were four non -device related deaths (heart failure
exacerbation, urosepsis, pulmonary embolism and microcellular pulmonary cancer).
The
results of the PARADIGM-101 study demonstrated that CGuard EPS can safely be used in a high risk, all-comer population of patients with
carotid artery stenosis and indicated that routine use of CGuard EPS may prevent cerebral events, such as strokes, by holding plaque
against the vessel wall, preventing emboli from being released into the blood stream. The PARADIGM-101 study found that CGuard EPS is
applicable in up to 90% of all-comer patients with carotid stenosis.
PARADIGM-500
(prospective evaluation of all-comer percutaneous carotid revascularization in symptomatic and increased-risk asymptomatic carotid artery
stenosis, using CGuard™ mesh-covered embolic prevention stent system-500) is an investigator-initiated, single center study designed
to evaluate the outcomes of routine CGuard EPS in consecutive all-comer patients accepted by a multidisciplinary committee for carotid
revascularisation. The PARADIGM-500 study is an extension of the of PARADIGM-101 study, which was initiated in 2015.
An
update of the PARADIGM-500 study was presented at the Veith 2024 conference in New York, held from November 19-23, 2024. Key
findings were:
●
30-day
death or stroke rate of 0.75%
●
30-day
death, stroke and myocardial infarction (DSMI) rate of 0.94%
●
12-month
freedom from ipsilateral stroke, in stent restenosis (ISR) and target lesion revascularization (TLR) combined rate of 99.6%
●
At
12-month, the ISR rate (by Core Lab) is lower than those reported in the literature of first-generation stents (Naylor R, et al. European
Society for Vascular Surgery (ESVS) 2023 Clinical Practice Guidelines on the Management of Atherosclerotic Carotid and Vertebral Artery
Disease. Eur J Vasc Endovasc Surg. 2023).
●
No
cases of stent thrombosis (0%) with CGuard EPS through 12 months of follow up
The
Paradigm-500 study confirms that carotid artery stenting (CAS) with the CGuard EPS stent delivers reliable and low rates of 30-day composite
DSMI, 12-month ipsilateral stroke, ISR and no instances of stent thrombosis in a wide range of patient at standard and high risk for
CEA.
Clinical
Results and Mechanical Properties of the Carotid CGUARD Double-Layered Embolic Prevention Stent Study
“Clinical
Results and Mechanical Properties of the Carotid CGUARD Double-Layered Embolic Prevention Stent Study” was an investigator-led,
prospective single-center study which evaluated CGuard EPS in 30 consecutive patients with internal carotid artery stenosis disease with
the objective of reporting early clinical outcomes with a novel MicroNet covered stent for the internal carotid artery and the in vitro
investigation of the device’s mechanical properties. In October 2016, the 30-day positive results were published online-ahead-of-print
in the Journal of Endovascular Therapy.
11
Key
findings from the study are as follows:
●
100%
success in implanting CGuard EPS without residual stenosis;
●
No
peri- or post-procedural complications;
●
No
deaths, major adverse events, minor or major strokes, or new neurologic symptoms during the six months following the procedure;
●
Modified
Rankin Scale improved for the symptomatic patients from 1.56 prior to the procedure to 0 afterwards;
●
All
vessels treated with CGuard EPS remained patent (open) at six months; and
●
DW-MRI
performed in 19 of 30 patients found no new ipsilateral lesions after 30 days and after six months compared with the baseline DW-MRI
studies.
Additionally,
based on engineering evaluations, the study concluded that CGuard EPS provides a high radial force and strong support in stenotic lesions.
The stent is easy to use and safe to implant because it does not foreshorten and its structure adapts well to changes in diameter and
direction of tortuous vascular anatomies. The MicroNet mesh of CGuard did not cause any changes to specific mechanical parameters of
the underlying stent.
Safety
and Efficacy of the New Micromesh-Covered Stent CGuard in Patients Undergoing Carotid Artery Stenting: Early Experience From a Single
Center
“Safety
and Efficacy of the New Micromesh-Covered Stent CGuard in Patients Undergoing Carotid Artery Stenting: Early Experience From a Single
Center” was an investigator-led, single-center study which evaluated CGuard EPS in 82 consecutive patients. The aim of the study
was to evaluate the safety (technical success) and efficacy (clinical success) of the CGuard stent system – a new nitinol stent
covered by a closed-cell polyethylene and terephthalate mesh designed to prevent embolic events. In 2017, the 30-day positive results
were published online-ahead-of-print in the European Journal of Vascular and Endovascular Surgery (2017), https://doi.org/10.1016/j.ejvs.2017.09.015.
Key
findings from the study are as follows:
●
100%
success in implanting CGuard EPS;
●
One
case of acute stent thrombosis occurred within 4 hours of the procedure:
●
One
minor stroke was recorded within the peri-operative period following the acute stent thrombosis, mentioned above;
●
No
new adverse neurological events were recorded at the post-operative period.
●
DW-MRI
was performed to assess the occurrence of new ischaemic brain lesions from the target vessel following placement of the CGuard stent
peri- (48-72 hours) and post-operatively (30 days) in 21 and 11 patients, respectively. Five of 21 patients (23.8%) had new ischaemic
brain lesions peri-operatively (48-72 hours) on the ipsilateral side, for a total number of 30 lesions, with an average lesion volume
of 0.039 +/- 0.025 cm3. Four patients (19.1%) had new ischaemic brain lesions on the contralateral side, for a total number of nine
lesions, with an average lesion volume of 0.019 +/- 0.011 cm3 (range 0.016-0.034 cm3). At the postoperative period, spontaneous resolution
was noted in all the lesions recorded in the peri-operative period in the 11 patients participating. Only one symptomatic patient
had two new ischaemic brain lesions (1 ipsilateral and 1 contralateral).
12
CGUARD
Mesh-Covered Stent in Real World: The IRON-Guard Registry
“CGUARD
Mesh-Covered Stent in Real World: The IRON-Guard Registry using CGuard EPS” was a physician initiated prospective multi-center
registry that included 200 patients from 12 medical centers in Italy. The objective of the study was to report 30-day outcomes (including
MACCE) in a prospective series of patients who were treated with CGuard EPS between April 2015 and June 2016. In January 2017, 30-day
results were presented at the Leipzig Interventional Course (LINC) 2017 and published in the Journal of EuroIntervention in May 2017.
The 12-month follow-up was published in the Journal of EuroIntevention in October 2018.
Key
30-day results presented were:
●
100%
success in implanting CGuard EPS;
●
No
MI, major stroke or death at 30 days;
●
There
were two transient ischemic attacks and five periprocedural minor strokes, including one thrombosis solved by surgery.
●
Total
elimination of post-procedural neurologic complications by 30 days;
●
DW-MRI
performed pre-procedure and between 24- and 72-hours post-procedure in 61 patients, indicated that 12 patients had new micro emboli
(19%).
●
At
12-month, there were no new major neurological adverse events, thrombosis or external carotid occlusion recorded;
●
One
myocardial infarction occurred at 12 months.
Initial
Clinical Study of the New CGuard EPS MicroNet Covered Carotid Stent: “One Size Fits All”
“Initial
Clinical Study of the New CGuard EPS MicroNet Covered Carotid Stent: ‘One Size Fits All’” was an investigator-led,
single-center study, which evaluated CGuard EPS in 30 consecutive patients with symptomatic stenosis of the internal carotid artery with
the objective of evaluating the CGuard EPS MicroNet covered stent for its ability to adjust to different vessel diameters. The results
of the study were published in the Journal of Endovascular Therapy in May 2019. The conclusion of the study as reported was that CGuard
EPS has high conformability combined with an almost equivalent outward radial force at expansion diameters ranging from 5.5 to 9.0 mm.
The first clinical results demonstrate the “One Size Fits All” stent can be implanted in internal carotid arteries with reference
diameters within this range.
13
Key
findings from the study were as follows:
●
100%
technical success in implanting CGuard EPS;
●
No
neurological events within 30 days;
●
The
chronic outward force normalized by stent length demonstrated a near-equivalent radial force outcome; and
●
The
stent displayed only a minor difference between the minimal radial force at 9.0 mm (0.195 N/mm) and the maximal radial force at 5.5
mm (0.330 N/mm).
Preliminary
Results from a Prospective Real-World Multicenter Clinical Practice of Carotid Artery Stenting Using the CGuard Embolic Prevention System:
The IRONGUARD 2 Study
“Preliminary
Results From a Prospective Real-World Multicenter Clinical Practice of Carotid Artery Stenting Using the CGuard Embolic Prevention System:
The IRONGUARD 2 Study” is a physician initiated prospective multi-center registry enrolling 733 patients from 20 medical centers
in Italy, from January 2017 to June 2019. The objective of the study is to evaluate periprocedural (24 hours), post-procedural (up to
30 days), and 12-month outcomes in a largest, prospective, multicenter series of patients submitted for protected carotid artery stenting
with the CGuard Embolic Prevention System. The 24-hour, 30-day and 12-month preliminary results (data available on 726 patients out of
the 733 treated) were presented at the Leipzig Interventional Course (LINC) in January 2021. The study’s preliminary results from
the IRONGUAURD 2 study suggested in a real-world evaluation of carotid artery stenting, CGuard EPS can be safely used for treatment of
extracranial carotid artery stenosis, allowing a low rate of post procedural adverse events by 12 months.
14
Key
findings from the study are as follows:
●
100%
procedural success in implanting CGuard EPS;
●
1
death from hemorrhagic stroke (patient was admitted for immediate treatment of CAS due to stroke), 2 minor strokes, 6 TIAs and one
nonfatal AMI at 24 hours;
●
1
minor stroke, 2 TIAs, three AMIs, no deaths and no stent thrombosis/occlusions between 24 hours and 30 days; and
●
1
minor stroke, 4 TIAs, 2 AMIs and 8 deaths (the 2 mentioned AMIs, 4 malignancies, 1 suicide and 1 undefined complication in Guillain-Barré
Syndrome) between 30 days and 1 year.
Thirty-Day
Results of the Novel CGuard-Covered Stent in Patients Undergoing Carotid Artery Stenting
“Thirty-Day
Results of the Novel CGuard-Covered Stent in Patients Undergoing Carotid Artery Stenting” was an investigator-led, prospective
single-center study which evaluated CGuard EPS in 103 patients that underwent carotid artery stenting procedures. The aim of the study
was to provide early-term evaluation, safety, and efficacy of the novel CGuard micromesh self-expanding stent with embolic protection
system (EPS). In April 2021, the 30-day positive results were published in the Journal of Endovascular Therapy, DOI: 10.1177/15266028211007466.
Key
findings from the study are as follows:
●
100%
technical success was achieved in all patients:
●
No
major adverse events (death, stroke, or myocardial infarction) at 30 days.
The
SIBERIA Trial for Carotid Artery Stenosis: A Randomized Controlled Trial of Conventional Versus Micronet™-Covered Stent Use in
Percutaneous Neuroprotected Carotid Artery Revascularization: Peri-procedural and 30-day Diffusion-Weighted Magnetic Resonance Imaging
and Clinical Outcomes (RCT trial)
“The
SIBERIA Trial for Carotid Artery Stenosis: A Randomized Controlled Trial of Conventional Versus Micronet™-Covered Stent Use in
Percutaneous Neuroprotected Carotid Artery Revascularization: Peri-procedural and 30-day Diffusion-Weighted Magnetic Resonance Imaging
and Clinical Outcomes” was an investigator-initiated randomized clinical trial, single-center study, which evaluated one hundred
patients who qualified for carotid revascularization with high risk for surgery and were randomized 1:1 to either CGuard EPS or Acculink TM .
The primary endpoints were incidence and volume of new cerebral embolic post-procedural lesions (24-48 hours) as determined by diffusion
weighted magnetic resonance imaging (DW-MRI). The principal secondary endpoints included incidence of periprocedural or postprocedural
stroke, myocardial infarction and death at 30 days. The 30-day results of the study were presented in a late-breaking session at the
EuroPCR in June 2020 and published (Randomized Controlled Trial of Conventional Versus MicroNet-Covered Stent in Carotid Artery Revascularization,
JACC Cardiovascular Interventions, Vol. 14, November 21, 2021). The conclusion of the study was that the CGuard™ Micronet™-covered
stent use in consecutive unselected patients subjected to neuroprotected carotid artery stenting was associated with a greater than three-fold
reduction in the procedure-generated mean cerebral lesion volume, and with zero post-procedural cerebral embolisms observed. The MicroNet
covered stent significantly reduced periprocedural and abolished post procedural cerebral embolism in relation to a conventional carotid
stent. This is consistent with the MicroNet covered stent’s sustained embolism prevention, translating into cerebral protection
not only during but after carotid artery stenting. The incidence of restenosis and vessel occlusion according to the ICA (internal carotid
artery) ultrasound and the incidence of strokes, myocardial infarctions or deaths between the study arms at 365 days were presented at
the LINC conference in Leipzig, Germany in June, 2022. The 12-month outcomes demonstrated a significantly higher prevalence of the combined
endpoint of death, stroke or myocardial infarctions and in-stent restenosis and vessel occlusion rate in the first generation (single
layer) carotid stent, Acculink TM , versus the MicroNet-Covered Stent, CGuard™.
15
Key
findings from the study are as follows:
●
Peri
Procedure, the CGuard™ arm was observed to have a 57% reduction in new cerebral lesion average volume per patient (171 mm 3
vs. 73 mm 3 ), a statistically significant improvement (p=0.017) and 222 mm 3 vs. 84 mm 3 (p=0.038);
●
Post
Procedure (24-48 hours), the CGuard™ arm was observed to have a 78% reduction in the average volume of new cerebral lesions
(157 mm 3 vs. 700 mm 3 ), a statistically significant improvement (p=0.007);
●
At
30 days, DW-MRI showed zero new cerebral lessons in the CGuard™ arm versus six in the Acculink™ arm (p=0.03);
●
At
30 days, there were zero strokes, myocardial infarctions or deaths in the CGuard arm and two events the Acculink™ arm (two
strokes);
●
At
365 there were zero cases of restenosis and vessel occlusion in the CGuard™ arm versus 3 cases of restenosis and 1 case of
vessel occlusion in the Acculink™ arm;
●
At
365 days, there were one event in the CGuard arm (one death) and five events the Acculink™ arm (two strokes, two deaths and
one myocardial infarction).
On-going
and Planned Clinical Trials
C-GUARDIANS
C-GUARDIANS
is a prospective, multicenter, single-arm, pivotal study to evaluate the safety and efficacy of the CGuard Carotid Stent System when
used to treat symptomatic and asymptomatic carotid artery stenosis in patients undergoing carotid artery stenting.
The
study completed enrollment in June 2023. The primary endpoint is a composite of: (1) incidence of major adverse events including Death
(all-cause mortality), any Stroke, and Myocardial Infarction (DSMI) through 30-days post index procedure, or (2) ipsilateral stroke from
day 31 to day 365 post-procedure. All events are adjudicated by an independent clinical events committee. The composite index will be
compared to a performance goal based on the observed rate of the two components of the primary endpoint from previous pivotal stent trials
which are considered industry standard. The performance goal will be considered met if the upper bound of the two-sided 95% confidence
interval calculated from the observed primary endpoint rate is < 11.6% and the p-value is less than 0.025.
From
July 2021 to June 2023, 316 patients were prospectively enrolled at 24 sites in the US and the EU and from April 2023 included deployment
of the CGuard stent using CGuard Prime, our next generation CAS stent platform. All CAS procedures were performed utilizing the CGuard
MicroNet TM mesh covered stent and cleared intra-procedural cerebral protection distal embolic filters or proximal embolic
protection with flow cessation, or both. At 30 days, the hierarchical DSMI rate was 0.95% in the intent to treat (ITT) analysis and 0.63%
in the per- protocol (PP) analysis. Three patients experienced major adverse cardiovascular events by 30-days: one patient who did not
take dual antiplatelet therapy (protocol violation) had a major stroke and died and two other patients had a stroke. There was no myocardial
infarction (MI). These results support a potential “neuroprotective” effect of the CGuard stent from the procedure to 30
days follow-up.
On
May 28, 2024, we announced positive one-year follow up results from the C-GUARDIANS trial of the CGuard™ Carotid Stent Systemin
which stenting with the CGuard Carotid Stent System in patients with carotid artery stenosis and at high risk for carotid endarterectomy
had a 30-day DSMI and Ipsilateral stroke between 31 and 365 days rate of 1.95%, measured from procedure to 1-year follow-up in the ITT
analysis, using Kaplan-Meier method. The primary endpoint rate was 1.71% in the per-protocol population.
On
September 16, 2024, we submitted the clinical module of the PMA, which is currently under interactive review with the FDA.
16
Early
Feasibility Study of CGuard EPS for Acute Stroke Patients with Tandem Lesions
In
November 2023, we announced the entry into a strategic agreement with the Jacobs Institute at the State University of New York at Buffalo
to execute an early feasibility study of CGuard Carotid Stent System for the treatment of acute stroke patients with tandem lesions.
The study, a prospective, single center, single-arm, open label, non-blinded study is expected to enroll 15 acute stroke patients across
three U.S. sites to assess the safety and feasibility of using CGuard Carotid Stent System to treat acute ischemic stroke patients with
tandem lesions. of Dr. Adnan Siddiqui, Vice-Chairman and Professor of Neurosurgery at the State University of New York at Buffalo, CEO
of the Jacobs Institute, is the Principal Investigator for the study. We began enrollment in the first quarter of 2025.
CGUARDIANS
II for TCAR procedures
On
October 3, 2024, FDA approved our IDE for CGUARDIANS II, a multicenter, single-arm, pivotal study to evaluate the safety and efficacy
of the CGuard Prime 80cm carotid stent system used in conjunction with the ENROUTE NPS during Transcarotid Artery Revascularization (TCAR)
procedure. Patrick Geraghty, M.D., professor of surgery and radiology, section of vascular surgery at Washington University School of
Medicine in St. Louis, MO, and Patrick Muck, M.D., program director and chief of vascular surgery at Good Samaritan Hospital in Cincinnati,
OH, are lead principal investigators for the trial. The study enrolled its first patient on December 16, 2024 and aims to enroll a minimum
of 50 evaluable patients.
CGUARDIANS
III for TCAR procedures using SwitchGuard NPS
The
SwitchGuard™ NPS is designed to allow the treating physician to reverse cerebral blood flow during a TCAR procedure. SwitchGuard™
is intended to prevent embolic debris generated during the procedure from traveling to the brain, passing the blood through the filter
before returning it to the patient to minimize blood loss.
On
December 30, 2024, we submitted an IDE to the FDA for CGUARDIANS III, a multicenter, single-arm, pivotal study to evaluate the safety
and efficacy of the SwitchGuard NPS used in conjunction with the CGuard Prime 80cm Carotid Stent System for providing cerebral embolic
protection during carotid artery stenting via the Transcarotid Artery Revascularization (TCAR) approach. The IDE submission is currently
under review at the FDA.
Growth
Strategy
Our
primary business objective is to utilize our proprietary MicroNet technology and products to become the industry standard for the treatment
of carotid disease and prevention of stroke and to provide a superior solution to the common acute problems caused by current stenting
procedures, such as restenosis, embolization and thrombosis. We are pursuing the following business strategies to achieve these objectives.
●
Grow our presence in existing and new markets for CGuard
EPS . We are focused on growing our presence in the U.S. market through a direct sales organization, pending FDA approval of CGuard
Prime and to this end have been building the infrastructure for U.S. commercial operations. In addition, we have launched CGuard
EPS in most European and Latin American countries through a comprehensive distributor sales organizations network. We are continuing
to focus on larger growing markets through this network by supporting our distributors with robust marketing and clinical education
programs. We are pursuing additional product registrations and distribution contracts with local distributors in other countries
in Europe, Asia and Latin America. In February 2021, we executed a distribution agreement with Chinese partners for the purpose of
expanding our presence in China. Currently, we are seeking strategic partners for a potential launch of CGuard EPS in Asian countries.
●
Widen
the adoption of CGuard . We are seeking to expand the population of CGuard patients in those countries in which CGuard is commercially
available. In particular, our focus is on establishing CGuard as a viable alternative (in appropriate cases) to carotid endarterectomy
and the use of conventional carotid stents within the applicable medical communities. We intend to accomplish this goal by continuing
to publish and present our clinical data, supporting investigator-initiated clinical registries and exploring the addition of additional
devices to our portfolio, including the SwithchGuard NPS for use in TCAR cases. We have partnered and will continue to seek out partnerships
with organizations focused on the treatment of stroke. We will also continue to engage advisory boards and to develop a network of
key opinion leaders to assist us in our efforts to widen the adoption of CGuard.
17
●
Portfolio
expansion and pipeline development We plan to continue to invest in advancing our portfolio with new delivery system alternatives
to facilitate the use of CGuard and SwitchGuard by all physicians. We believe our delivery systems, if approved, will enable all
endovascular access points including accessory devices for trans carotid artery revascularization .
●
CMS
approval of National Coverage Determination (NCD) – On October 11 2023, CMS issued an NCD covering the use of carotid stents
(both CAS and TCAR) for the treatment of both symptomatic and asymptomatic patients either at high- or standard-surgical risk. This
decision significantly increases the available market to endovascular procedures. Previously, only symptomatic patients at high-risk
to surgery were covered through the CMS coverage, NCA - Percutaneous Transluminal Angioplasty (PTA) of the Carotid Artery Concurrent
with Stenting (CAG-00085R8) - Tracking Sheet (cms.gov)
●
Continue
to leverage our MicroNet technology to develop additional applications for interventional cardiologists and vascular surgeons. In
addition to the applications described above, we believe that we will eventually be able to utilize our proprietary MicroNet technology
to address imminent market needs for new product innovations to significantly improve patient care. We continue to broadly develop
and protect intellectual property using our mesh technology. Examples of some areas include peripheral vascular disease and neurovascular
disease.
●
Establish
relationships with collaborative and development partners to fully develop and market our existing and future products. We are
seeking strategic partners for collaborative research, development, marketing, distribution, or other agreements, which could assist
with our development and commercialization efforts for CGuard and other potential products that are based on our MicroNet technology.
Competition
The
markets in which we compete are highly competitive, subject to change and impacted by new product introductions and other activities
of industry participants.
Carotid
With
respect to competition for our carotid embolic prevention system, CGuard EPS, the manufacturers of products used in connection with CAS
procedures include a number of large companies, such as Abbott Laboratories, Boston Scientific Corporation, Medtronic, Cordis Corporation
and Terumo Medical Corporation.
Many
of these competitors are larger companies or divisions of publicly traded companies that have certain competitive advantages, including
greater capital resources, larger customer bases, broader product lines, larger sales forces, greater marketing and management resources,
larger research and development staffs and larger facilities than ours and have established reputations, relationships with our target
customers and worldwide distribution methods that are more effective than ours. However, while there are currently many market participants
in the U.S. carotid stent market, we believe that the European market is somewhat more fragmented for CAS products, and, in our opinion,
smaller competitors may be able to gain market share with greater flexibility and more efficiency than in the United States.
18
We
believe the principal competitive factors in our market include the following:
●
Strength
of clinical evidence- patient outcomes and adverse event rates
●
Scale
and effectiveness of commercialization efforts/organizations
●
Acceptance
by treating physicians and referral sources
●
Physician
learning curve
●
Ease-of-use
and reliability
●
Economic
benefits and cost savings
●
●
Availability
of reimbursement
Patient
experience
Sales
and Marketing
Sales
and Marketing
In
October 2024, we established our global headquarters in Miami, Florida to support the anticipated U.S. launch and commercialization of
the CGuard Prime carotid stent system. During 2024, we started the build-out of the infrastructure for commercial operations in the U.S.
designed to support the anticipated commercialization of the CGuard Prime carotid stent system.
We
are designing our commercial strategy and building our direct sales force to drive CGuard Prime penetration within the community of interventionalists.
In parallel, we aim at transitioning vascular surgeons from carotid endarterectomy procedures to CAS and TCAR with CGuard and accessory
devices, which we believe can greatly expand our customer base. We plan to continue to focus our marketing efforts on key growth markets
and to evaluate opportunities in new territories as they become available. In addition, we are using international medical conferences
to gain market exposure and brand recognition. We continue to work with leading physicians to enhance our marketing efforts and are developing
relationships with new key opinion leaders to champion our technology and work with us in clinical studies.
In
the United States, we plan to market and sell the CGuard Prime carotid stent system through a direct sales organization consisting of
15 sales and clinical support personnel, as of March 12, 2025. Our sales professionals have substantial experience launching and establishing
new disruptive therapies and converting open surgical procedures to minimally-invasive alternatives. We are continuing to expand our
commercialization capabilities and to build our distribution capabilities to support the anticipated commercialization of the CGuard
Prime carotid stent system. At this time, we do not have any commercially approved medical devices in the US, and we have not registered
as an establishment with the FDA.
Previously,
based on the positive CGuard EPS clinical data, we initiated the commercial launch of CGuard EPS in CE marked countries in early 2015.
In September 2015, we announced full market launch of CGuard EPS in Europe. Since 2017 we have focused on sales of our products through
local distribution partners and our own internal sales initiatives to gain greater reach into all the relevant clinical specialties and
to expand our geographic coverage.
Product
Positioning
We
believe that CGuard has the potential to become the standard of care in treating carotid artery disease. It is a second-generation stent
with positive patient outcomes demonstrating significant reduction in post-procedural neurological events.
Additionally,
we intend to continue to evaluate potential product and manufacturing enhancements for CGuard expected to reduce cost of goods or provide
the best-in-class performing delivery system and accessory solutions. We believe these improvements may allow us to reduce cost of goods
and increase penetration in our existing geographies and better position us for entry into new markets.
19
Insurance
Reimbursement
While
most countries have established reimbursement codes for stenting procedures, certain countries may require additional clinical data before
recognizing coverage and/or to obtain a certain level of reimbursement for one or more of our products. In these situations, we intend
to complete the required clinical studies to obtain reimbursement approval in countries where it makes economic sense to do so.
In
October 2023, CMS issued its final National Coverage Determination (“NCD”), expanding coverage of both CAS and TCAR to include
both asymptomatic and standard risk patients, significantly expanding the U.S. addressable market.
Intellectual
Property
Patents
We
have 66 issued patents, including 20 patents issued in the U.S., and 27 pending patent applications, 6 of which are pending in the United
States. Many of these patents and applications cover aspects of our CGuard and MGuard technology. Patents outside the U.S. have been
filed in Canada, China, Europe, Israel, India, Japan, Australia, and South Africa. The patents and applications fall into a number of
patent families, as listed below:
Base Title of Patent Family
Pending patent
applications
(Countries)
Issued patents
(Country
and Patent No.)
Issue Date
Bifurcated stent assemblies
USA
China
8,961,586
ZL 20078046676.2
24-Feb-2015
26-Sep-2012
Deformable tip for stent delivery and methods of use
USA
Israel
10,258,491
260,945
16-Apr-2019
01-Jul-2020
Handle for Two-Stage Deployment of a Stent
Europe
China
Japan
India
USA
USA
11,839,561
12-Dec-2023
Shunts with Blood-Flow Indicators
Europe
India
USA
Hong Kong
Japan
China
Hong Kong
USA
China
Japan
11,844,893
ZL 2022800089963
7449627
19-Dec-2023
26-Nov-2024
06-Mar-2024
Device for Shunting Blood Between the Arterial and Venous Systems
Europe
India
Hong Kong
USA (CON)
China (DIV)
Japan (DIV)
Hong Kong
USA
China
Japan
12,070,542
ZL 2022800098002
7576884
27-Aug-2024
10-Sep-2024
24-Oct-2024
Devices for shunting blood
USA
China
Europe
India
Japan
In Vivo Filter Assembly
USA
9,132,261
15-Sep-2015
Knitted Stent Jackets
USA
China
India
Canada
China
Canada
Germany
France
UK
10,137,015
ZL200780046697.4
323792
2666728
ZL201210320950.3
2887189
EP2076212
EP2076212
EP2076212
27-Nov-2018
10-Oct-2012
28-Oct-2019
23-Jun-2015
02-Dec-2015
01-May-2018
29-Mar-2017
29-Mar-2017
29-Mar-2017
20
Optimized
stent jacket
USA
Europe
Canada
China
India
China
USA
USA
USA
USA
Israel
USA
USA
Canada
Belgium
Switzerland
Germany
France
UK
Italy
Ireland
Luxembourg
Netherlands
Europe
UK
Germany
France
Ireland
10,070,976
EP2088962
2670724
ZL20078043259.2
297257
ZL201210454357.8
9,132,003
9,782,281
9,526,644
10,406,006
230,922
10,406,008
11,051,959
3,013,758
EP2088962
2088962
2088962
2088962
2088962
2088962
2088962
2088962
2088962
EP3292837
EP3292837
EP3292837
EP3292837
EP3292837
11-Sep-2018
11-Oct-2017
11-Dec-2018
02-Jan-2013
30-May-2018
09-Dec-2015
15-Sep-2015
10-Oct-2017
27-Dec-2016
10-Sep-2019
01-Oct-2020
10-Sep-2019
06-Jul-2021
14-Sep-2021
11-Oct-2017
11-Oct-2017
11-Oct-2017
11-Oct-2017
11-Oct-2017
11-Oct-2017
11-Oct-2017
11-Oct-2017
11-Oct-2017
09-Nov-2022
09-Nov-2022
09-Nov-2022
09-Nov-2022
09-Nov-2022
Stent
apparatus for treatment via body lumens and methods of use
Europe
(Div)
Europe
China
USA
Canada
South
Africa
USA
Canada
USA
USA
Germany
France
UK
Ireland
Italy
Switzerland
2609687
2007/10751
10,070,977
2843097
10,058,440
10,932,926
EP1885281
EP1885281
EP1885281
EP1885281
EP1885281
EP1885281
22-Apr-2014
27-Oct-2010
11-Sep-2018
27-Oct-2015
28-Aug-2018
02-Mar-2021
13-Feb-2019
13-Feb-2019
13-Feb-2019
13-Feb-2019
13-Feb-2019
13-Feb-2019
Stent
Thermoforming Apparatus and Methods
USA
USA
Japan
9,527,234
10,376,393
6553178
27-Dec-2016
13-Aug-2019
12-Jul-2019
Methods
of using a self-adjusting stent assembly and kits including same
USA
China
11,684,498
ZL
2019800679437
27-Jun-2023
03-May-2022
Intravascular
sheath
USA
(UTI)
PCT
21
The
patents and patent applications listed above cover various aspects of our products, specifically focusing on the mesh sleeve covering
our stents, as well as methods for production and delivery mechanisms of the stents. We believe that our patents, in particular those
covering the use of a knitted micron-level mesh sleeve over a stent for various indications, as well as our pending patent applications
(if issued as patents with claims substantially in their present form), create a significant barrier against other companies seeking
to use similar technology. We believe these patents and patent applications collectively cover all our existing products and may be useful
in protecting our future technological developments. We intend to aggressively continue patenting new technologies and to actively pursue
any infringement of our key patents.
Trade
Secrets
We
also rely on trade secret protection to protect our interests in proprietary know-how and/or for processes for which patents are difficult
to obtain or enforce. As part of our trade secret policy, we rely on non-disclosure and confidentiality agreements with employees, consultants
and other parties to protect trade secrets and other proprietary technology.
Trademarks
We
have registered or applied to register the following trademarks, which we use in connection with our products:
●
InspireMD ®
(US, European Union, and UK)
●
MGuard ®
(European Union, and UK)
●
CGuard ®
(US, European Union, and UK)
●
MGuard
Prime ® (European Union, and UK)
●
NGuard ®
(European Union and UK)
●
PVGuard®
(European Union, and UK)
●
Micronet®
(US)
●
(MNP
Micronet Protection logo) (European Union and UK)
●
Carenet®)European
Union and UK)
●
SmartFit™
(US, UK, EP and CN)
●
SmartFit
Logo (EP, UK, CN)
●
CGuard
Prime (EP, UK, US, CN, JP)
●
SwitchGuard
(EP, UK, US, JP)
●
True
North Medical (EP, UK)
●
MicroMesh
logo (EP, UK)
●
Micronet
logo (updated version) (US, EP, UK, JP)
The
trademarks are renewable indefinitely, so long as we continue using the marks and make the appropriate filings when required. We also
use and may have common-law rights to various trademarks, trade names, and service marks.
Government
Regulation
The
manufacture and sale of our products are subject to regulation by numerous governmental authorities, principally the European Union CE
mark and other corresponding foreign agencies.
Sales
of medical devices outside the United States are subject to foreign regulatory requirements that vary widely from country to country.
These laws and regulations range from simple product registration requirements in some countries to complex approval process, clinical
trials and production controls in others. As a result, the processes and time periods required to obtain foreign marketing approval may
be longer or shorter than those necessary to obtain FDA market authorization. These differences may affect the timeliness of international
market introduction of our products. For the European Union nations, medical devices must obtain a CE mark before they may be placed
on the market. In order to obtain and maintain the CE mark, we must comply with EU law on medical devices, which, until May 26, 2021
was governed by the MDD, by presenting comprehensive technical files for our products demonstrating safety and efficacy of the product
to be placed on the market and passing initial and annual quality management system audit as per ISO 13485 standard by a European Notified
Body. We have obtained ISO 13485 quality system certification and CGuard EPS that we currently distribute into the European Union, displays
the required CE mark. In order to maintain certification, we are required to pass an annual surveillance audit conducted by Notified
Body auditors. The European Union replaced the MDD with the new MDR regulation. The MDR entered into force after a transitional period
of three years and a one year extension of that transition period due to the COVID-19 pandemic on May 26, 2021 and which changes several
aspects of the regulatory framework in the European Union. Manufacturers had the duration of the transition period to update their technical
documentation and processes to meet the new requirements in order to obtain a CE Mark. In January 2024, we received CE mark recertification
of CGuard EPS under the MDR.
22
We
have or had regulatory approval and made sales of CGuard EPS either through distributors pursuant to distribution agreements or directly,
in the countries listed in the table below. While each of the European Union member countries accepts the CE mark as its sole requirement
for marketing approval, some of these countries still require us to take additional steps in order to gain reimbursement rights for our
products. Furthermore, while we believe that certain of the below-listed countries that are not members of the European Union and accept
the CE mark as a primary requirement for marketing approval, each such country requires additional regulatory requirements for final
marketing approval of our products. Furthermore, we are currently targeting additional countries in Europe, Asia, and Latin America;
however, even if all governmental regulatory requirements are satisfied in each such country, we anticipate that obtaining marketing
approval in each country could take as few as three months or as many as twelve months or more, due to the nature of the approval process
in each individual country, including typical wait times for application processing and review, as discussed in greater detail below.
Please
refer to the table below setting forth the approvals and sales made for CGuard EPS on a country-by-country basis
Approvals
and Sales of CGuard EPS on a Country-by-Country Basis*
Countries
CGuard EPS
Approval
CGuard EPS
Sales
Argentina
Y
Y
Australia
Y
Y
Austria
Y
Y
Belarus
Y
Y
Belgium
Y
Y
Brazil
Y
Y
Bulgaria
Y
Y
Chile
Y
Y
Colombia
Y
Y
Croatia
Y
N
Cyprus
Y
Y
Czech Republic
Y
Y
Denmark
Y
N
Dominican Republic
N
N
Ecuador
Y
N
Estonia
Y
Y
Finland
Y
Y
France
Y
Y
Germany
Y
Y
Greece
Y
Y
Netherlands
Y
Y
Hong Kong
N
N
Hungary
Y
N
Iceland
N
N
India
Y
Y
Ireland
Y
N
Israel
Y
Y
Italy
Y
Y
Kazakhstan
Y
Y
Latvia
Y
N
Lithuania
Y
Y
Liechtenstein
Y
N
Luxembourg
Y
N
Malaysia
N
N
Malta
Y
N
Mexico
Y
Y
Moldova
Y
Y
Montenegro
N
N
New Zealand
Y
N
Norway
Y
N
23
Peru
Y
Y
Poland
Y
Y
Portugal
Y
Y
Romania
Y
Y
Russia
Y
Y
Saudi Arabia
N
N
Serbia
Y
Y
Slovakia
Y
N
Slovenia
Y
Y
South Africa
Y
Y
Spain
Y
Y
Sweden
Y
Y
Switzerland
Y
Y
Turkey
N
N
Taiwan
Y
Y
Venezuela
N
N
Vietnam
Y
Y
Ukraine
Y
Y
United Kingdom
Y
Y
United States
N
Y
(1)
(1)
Refers
to CGuard units used in our ongoing FDA trial.
FDA
Government Regulation of Medical Devices for Human Subjects
Many
of our activities are subject to regulatory requirements by the FDA under provisions of the Federal Food, Drug, and Cosmetic Act and
regulations and guidance thereunder, including requirements governing the development, marketing, labeling, promotional efforts, manufacturing,
and exporting of medical devices.
FDA
Approval/Clearance Requirements
In
the United States, most Class II or III medical devices must be cleared or approved by the FDA prior to commercialization. Unless an
exemption applies, each medical device that is marketed in the United States must receive either 510(k) clearance or PMA approval. Medical
devices that are class II devices generally receive 510(k) clearance are “cleared” by the FDA to market, distribute, and
sell in the United States. Medical devices that are class III devices obtain a premarket approval by the FDA are “approved”
to market, distribute, and sell in the United States.
Class
I devices are those for which safety and effectiveness can be assured by adherence to the FDA’s general regulatory controls
for medical devices, or the General Controls, which include compliance with the applicable portions of the FDA’s quality system
regulations, facility registration and product listing, reporting of adverse medical events, and appropriate, truthful and non-misleading
labeling, advertising, and promotional materials. Some Class I devices also require premarket clearance by the FDA through the 510(k)-process
described below.
Class
II devices are generally required to file a Premarket review, known as a 510(k) application, that may also require General Controls,
and any other special controls as deemed necessary by the FDA to ensure the safety and effectiveness of the device. Generally, the 510(k)
submission is generally considered “substantially equivalent to a previously marketed device. Pursuant to the Medical Device User
Fee and Modernization Act of 2002 (MDUFMA), as of October 2002, unless a specific exemption applies, 510(k) submissions are subject to
user fees. Certain Class II devices are exempt from this premarket review process.
24
Class
III devices generally are more complex devices or new devices where there is no substantially equivalent device on the market and
can have the greatest risk. Devices in this class must demonstrate safety and efficacy requirements and file a premarket filing reviewed
by the FDA. In addition, Class III devices cannot generally be marketed until they receive FDA approval. The safety and effectiveness
of Class III devices cannot be assured solely by the General Controls and the other requirements described above. These devices generally
require formal clinical studies to demonstrate safety and effectiveness. Under MDUFMA, PMAs (and supplemental PMAs) are subject to significantly
higher user fees than 510(k) applications, and they also require considerably more time and resources.
The
FDA establishes requirements whether a device must undergo either the 510(k) clearance or premarket approval based on statutory criteria
that utilize a risk-based classification system. Premarket approval (PMA) is the FDA process of scientific and regulatory review to evaluate
the safety and effectiveness of Class III medical devices and, such reviews may also be done for Class II medical devices. Class III
devices are those that support or sustain human life, are of substantial importance in preventing impairment of human health, or which
present a potential, unreasonable risk of illness or injury. The FDA uses these criteria to decide whether a premarket approval or a
510(k) is appropriate, including the level of risk that the agency perceives is associated with the device and a determination by the
agency of whether the product is a type of device that is similar to devices that are already legally marketed. Devices deemed to pose
relatively less risk are placed in either Class I or II. In many cases, the FDA requires the manufacturer to submit a 510(k) requesting
clearance (also referred to as a premarket notification), unless an exemption applies. The 510(k) must demonstrate that the manufacturer’s
proposed device is “substantially equivalent” in intended use and in safety and effectiveness to a legally marketed predicate
device. A “predicate device” is a pre-existing medical device to which equivalence can be drawn, generally by a Class II
device that was in commercial distribution before May 28, 1976, for which the FDA has not yet called for submission of a PMA. A product
that lacks a predicate device may default to a Class III device, although a company may seek to submit a De Novo classification request,
rather than a PMA. The De Novo request allows a regulatory pathway to classify novel medical devices for which no predicate device exists,
and FDA will determine which category is appropriate for that device and for which general controls alone, or general and special controls,
provide reasonable occurrence of safety and effectiveness for the intended use, but for which there is no legally marketed predicate
device.
Premarket
Approval Pathway
The
CGuard Carotid Stent System is classified as a Class III medical device (considered a PMA) by the FDA. Class III medical devices are
generally the highest risk devices and are subject to more rigorous regulatory requirements by the FDA, since the FDA process of premarket
approval involves scientific and regulatory review to evaluate the safety and effectiveness of Class III medical devices for the purpose(s)
intended. The FDA will either approve or deny a premarket approval application and we cannot market a device until the FDA approves a
premarket approval application.
A
PMA must be supported by extensive data including, but not limited to, analytical, preclinical, clinical trials, manufacturing, statutory
preapproval inspections, and labeling to demonstrate to the FDA’s satisfaction the safety and effectiveness of the device is safe
and effective for its intended use. Before a premarket approval application is submitted, a manufacturer must generally apply for an
Investigational Device Exemption (IDE) to conduct clinical trials. If the device presents a “significant risk,” as defined
by the FDA, to human health, the FDA requires the device sponsor to file an IDE application with the FDA and obtain IDE approval prior
to initiation of broader human clinical trials.
Part
of the PMA process is to ensure that the IDE is the first application that must be supported by appropriate data, such as analytical,
animal and laboratory testing results, manufacturing information, and an Investigational Review Board (IRB) approved protocol showing
that it is safe to test the device in humans and that the testing protocol is scientifically sound, as well as ensuring patient informed
consent is obtained.
A
clinical trial may be suspended by either the FDA or the IRB at any time for various reasons, including a belief that the risks to the
study participants outweigh the benefits of participation in the study. Even if a study is completed, clinical testing results may not
demonstrate the safety and efficacy of the device, or they may be equivocal or otherwise insufficient to obtain approval of the product
being tested. After the clinical trials have been completed, if at all, and the clinical trial data and results are collected and organized,
a manufacturer may complete a premarket approval application.
25
Following
the IDE, a PMA application must be prepared and after a PMA is sufficiently complete, then the FDA will accept the application and begin
an in-depth review of the submitted information. By statute, the FDA has 180 days to review the “accepted application,” although,
generally, FDA review of the application generally takes between one and three years, but it may take significantly longer. During this
review period, the FDA may request additional information or clarification of information already provided. Also, during the review period,
an advisory panel of experts from outside the FDA may be convened to review and evaluate the application and provide recommendations
to the FDA as to the approvability of the device. The preapproval inspections conducted by the FDA include an evaluation of the manufacturing
facility to ensure compliance with the Quality Systems Regulations, as well as inspections of the clinical trial sites by the Bioresearch
Monitoring group to evaluate compliance with good clinical practice and human subject protections. New premarket approval applications
or premarket approval supplements are required for modifications that affect the safety or effectiveness of the device, including, for
example, certain types of modifications to the device’s indication for use, manufacturing process, labeling and design. Significant
changes to an approved premarket approval require a 180-day supplement, whereas less substantive changes may utilize a 30-day notice,
or a 135-day supplement. Premarket approval supplements often require submission of the same type of information as a premarket approval
application, except that the supplement is limited to information needed to support any changes from the device covered by the original
premarket approval application, and it may not require as extensive clinical data or the convening of an advisory panel.
510(k)
Clearance Pathway
We
do not currently market, distribute, or sell any products that have market clearance by the FDA under its 510(k) process that are generally
required as Class II devices. If, in the future, we develop products where 510(k) clearance is required, we would be required to submit
a 510(k) demonstrating that such proposed devices are substantially equivalent to a respective previously cleared 510(k) device or a
device that was in commercial distribution before May 28, 1976, for which the FDA has not yet called for the submission of 510(k). The
FDA’s 510(k) clearance pathway is established as 180 days for review, however, it usually takes from three to twelve months but
could take longer. In some cases, the FDA may require additional information, including clinical data, to make a determination regarding
substantial equivalence.
If
a device receives 510(k) clearance, any modification that could significantly affect its safety or effectiveness, or that would constitute
a new or major change in its intended use, will require a new 510(k) clearance or, depending on the modification, a premarket approval.
The FDA requires each device manufacturer to determine whether the proposed change requires submission of a new 510(k) or a premarket
approval, but the FDA can review any such decision and can disagree with a manufacturer’s determination. If the FDA disagrees with
a manufacturer’s determination, the FDA can require the manufacturer to cease marketing and/or recall the modified device until
510(k) clearance or premarket approval of the modified device is obtained.
Pervasive
and Continuing FDA Regulation
A
host of regulatory requirements apply to our devices, including the quality system regulation (which requires manufacturers to follow
elaborate design, testing, control, documentation and other quality assurance procedures), the Medical Device Reporting regulations (which
require that manufacturers report to the FDA specified types of adverse events involving their products), labeling regulations, and the
FDA’s general prohibition against promoting products for unapproved or “off-label” uses. Class II devices also can
have special controls such as performance standards, post-market surveillance, patient registries, and certain FDA guidelines may also
apply to Class I devices.
26
A
noncomprehensive list of the regulatory requirements that apply to our products classified as medical devices include:
●
product
listing and establishment registration, which helps facilitate FDA inspections and other regulatory action;
●
Quality
Systems Regulations, which requires manufacturers, including third-party manufacturers, to follow stringent design, testing, control,
documentation and other quality assurance procedures during all aspects of the development and manufacturing process;
●
labeling
regulations and FDA prohibitions against the promotion of products for uncleared, unapproved or off-label use or indication;
●
clearance
of product modifications that could significantly affect safety or efficacy or that would constitute a major change in intended use
of one of our cleared devices (if obtained);
●
approval
of product modifications that affect the safety or effectiveness of one of our cleared devices (if obtained);
●
medical
device reporting regulations, which require that manufacturers comply with FDA requirements to report if their device may have caused
or contributed to a death or serious injury, or has malfunctioned in a way that would likely cause or contribute to a death or serious
injury if the malfunction of the device or a similar device were to recur;
●
post-approval
restrictions or conditions, including post-approval study commitments;
●
post-market
surveillance regulations, which apply when necessary to protect the public health or to provide additional safety and effectiveness
data for the device;
●
the
FDA’s recall authority, whereby it can ask, or under certain conditions order, device manufacturers to recall from the market
a product that is in violation of governing laws and regulations;
●
regulations
pertaining to voluntary recalls; and,
●
notices
of corrections or removals.
At
this time, we do not have any commercially approved medical devices in the US, and we have not filed for an Establishment Registration
with the FDA. If we are approved or cleared to manufacture, prepare, or process a device in the United States, we and any third-party
manufacturers that we may use will be required to register our establishments with the FDA. In addition, we and our manufacturing facilities
will be subject to FDA inspections for compliance with the FDA’s Quality System Regulation. Additionally, some of our subcontractors
may also be subject to FDA announced and unannounced inspections for compliance with the FDA’s Quality System Regulation and assurances
that the Company is marketing appropriately the indications for use of the product. These regulations will require that we manufacture
our products and maintain our documents in a prescribed manner with respect to design, manufacturing, testing and quality control activities
and ensure that marketing materials and promotion are in compliance. As a medical device manufacturer, we will further be required to
comply with FDA requirements regarding the reporting of adverse events associated with the use of our medical devices, as well as product
malfunctions that would likely cause or contribute to death or serious injury if the malfunction were to recur. FDA regulations also
govern product labeling and prohibit a manufacturer from marketing a medical device for unapproved applications.
27
U.S.
Healthcare Laws and Regulations
In
addition to the FDA regulations, there are a variety of other healthcare laws and regulations to which we may be subject if any of our
products are marketed, sold, distributed, and/or utilized in the United States. In the United States, we may be subject to the oversight
of FDA, Office of the Inspector General within the Department of Health and Human Services (OIG), the Center for Medicare and Medicaid
Services (CMS), the Department of Justice (DOJ), in addition to other governmental reviews. We supply products that may be reimbursed
by federally funded programs such as Medicare. As a result, our activities may be subject to regulation by CMS and potential enforcement
by CMS, OIG and DOJ. Of specific note are federal and state fraud and abuse laws, which prohibit the payment or receipt of kickbacks,
bribes or other remuneration, including the offer or solicitation of such payment, intended to induce or reward the purchase, recommendation
or generation of business involving healthcare products any item or service payable by a health-care program. Other provisions of federal
and state laws prohibit presenting, or causing to be presented, to third party payors (including, government programs, such as Medicare
and Medicaid) for reimbursement, claims that are false or fraudulent, or which are for items or services that were not provided as claimed.
In addition, other healthcare laws and regulations may apply, such as transparency and reporting requirements and privacy and security
requirements. Violations of these laws can lead to civil and criminal penalties, including exclusion from participation in federal and
state healthcare programs, any of which could have a material adverse effect on our business. These laws are potentially applicable to
manufacturers of products regulated by the FDA as medical devices, such as us, and hospitals, physicians and other institutional or individual
providers that may refer or purchase such products. The healthcare laws that may be applicable to our business or operations include,
but are not limited to:
●
The
federal Anti-Kickback Statute, which prohibits a person from knowingly and willfully offering, soliciting or receiving any remuneration,
directly or indirectly, overtly or covertly, in cash or in kind, in return for or to induce referring or recommending an individual
to another person to receive items or services or to purchase, lease, order, or arrange for any good, facility, item or service payable
in whole or in part under a Federal health care program;
●
Federal
false claims laws and civil monetary penalty laws, including the False Claims Act, prohibit, among other things, individuals or entities
from knowingly presenting, or causing to be presented, claims for payment from Medicare, Medicaid or other government healthcare
programs that are false or fraudulent, or making a false statement to avoid, decrease or conceal an obligation to pay money to the
federal government. The False Claims Act imposes liability on any person or entity that, among other things, knowingly presents,
or causes to be presented, a false or fraudulent claim for payment by a federal health care program, knowingly makes, uses or causes
to be made or used, a false record or statement material to a false or fraudulent claim, or knowingly makes a false statement to
avoid, decrease or conceal an obligation to pay money to the U.S. federal government. The federal Civil Monetary Penalties Law prohibits,
among other things, the offering or transferring of remuneration to a Medicare or Medicaid beneficiary that the person knows or should
know is likely to influence the beneficiary’s selection of a particular supplier of Medicare or Medicaid payable items or services;
●
The
federal Health Insurance Portability and Accountability Act of 1996 (“HIPAA”), which includes provisions that prohibit
knowingly and willfully executing, or attempting to execute, a scheme to defraud any healthcare benefit program or obtain, by means
of false or fraudulent pretenses, representations, or promises, any of the money or property owned by, or under the custody or control
of, any healthcare benefit program, and for knowingly and willfully falsifying, concealing or covering up a material fact or making
any materially false statements in connection with the delivery of or payment for healthcare benefits, items or services;
●
HIPAA,
as amended by the Health Information Technology for Economic and Clinical Health Act of 2009, and its implementing regulations, including
privacy protection that impose obligations and requirements on healthcare providers, health plans, and healthcare clearinghouses
as well as their respective business associates that perform certain services for them that involve the use or disclosure of individually
identifiable health information, with respect to safeguarding the privacy and security of certain individually identifiable health
information;
28
●
The
federal transparency requirements under the Affordable Care Act, including the provision commonly referred to as the Open Payments
Act or Physician Payments Sunshine Act, which requires certain manufacturers of drugs, devices, biologics and medical supplies that
are reimbursable under Medicare, Medicaid or Children’s Health Insurance Program to report annually to Centers for Medicare
and Medicaid Services (“CMS”) information related to payments and other transfers of value to physicians and teaching hospitals,
and ownership and investment interests held by physicians and their immediate family members; and
●
Analogous
state and foreign laws and regulations, such as state anti-kickback and false claims laws, which may be broader in scope and apply
to referrals and items or services reimbursed by both governmental and non-governmental third-party payors, including private insurers,
many of which differ from each other in significant ways and often are not preempted by federal law, thus complicating compliance
efforts.
Customers
Our
customer base is varied. We currently have distribution agreements for our CE mark-approved CGuard EPS with medical product distributors
based in Europe, the Middle East, Asia Pacific and Latin America, and are in discussions with additional potential partners.
Our
distribution agreements stipulate that, while we shall assist in training by providing training materials, marketing guidance, marketing
materials, and technical guidance, each distributor will be responsible for carrying out local registration, sales and marketing activities.
In addition, in most cases, all sales costs, including sales representatives, incentive programs, and other marketing activities, will
be borne by the distributor. Under current agreements, distributors purchase stents from us at a fixed price. Our current agreements
with distributors are generally for a term of two to three years.
Upon
potential PMA approval in the U.S., our direct sales organization will support a varied customer base of multiple interventional and
surgical specialties, to include interventional cardiologists, neurologists, neuroradiologists and radiologists, as well as both vascular
and neurosurgeons.
Manufacturing
and Suppliers
The
polymer fiber for MicroNet is supplied by Biogeneral, Inc., a San Diego, California-based specialty polymer manufacturer for medical
and engineering applications.
Our
catheter supplier for CGuard EPS supplies us with catheters that help create the base for our CGuard EPS stents. Our agreement with the
supplier may be terminated by us upon eight months’ notice. On September 17, 2019, we amended the agreement with the supplier so
that we are responsible for purchasing and handling inventory of components used in the manufacturing of CGuard EPS catheters, and they
are responsible for the manufacturing process.
Our
catheter supplier for CGuard Prime supplies us with catheters that help create the base for our CGuard Prime stent system. Our agreement
with the supplier which may be terminated by us upon 9 months’ notice, calls for non-binding minimum orders.
We
currently manufacture our CGuard EPS and our CGuard Prime at our own facility. The self-expanding bare-metal stents for our CGuard EPS
and our CGuard Prime are being manufactured and supplied by a third-party. Our agreement with the supplier for the production of electro
polished nitinol bare-metal stents for CGuard EPS and CGuard Prime is priced on a per-stent basis, subject to the quantity of stents
ordered. The complete assembly process for CGuard EPS and CGuard Prime, including knitting and securing the sleeve to the stent and the
crimping of the sleeved stent into a delivery catheter, is done at our manufacturing site in Israel. Once CGuard EPS and CGuard Prime
have been assembled, they are sent for sterilization in a third-party facility in Israel, and then back to our facility for final packaging
and distribution.
29
To
support our anticipated production growth following the anticipated commercialization of the CGuard Prime carotid stent system, we
have engaged Aptyx Interventional Systems(“Aptyx”) a contract manufacturer that is a developer and manufacturer of
complex components and devices for the life sciences, to transfer the manufacturing of CGuard Prime finished goods to full-scale
production at their ISO Class 7 cleanroom facility in North Carolina. We previously engaged Medical Murray, another contract
manufacturer that specializes in medical device development, prior to Aptyx’s acquisition of Medical Murray’s ISO Class
7 cleanroom facility in North Carolina. Aptyx specializes in complex catheter and implant manufacturing and is FDA-registered and
ISO 13485-certified. The transfer includes setting up a production line, conducting process validations, and implementing quality
control measures to meet our specifications. Aptyx will also conduct operator training, execute qualification builds, and validate
the sterilization process for the CGuard Prime device. We expect this transition to enable increased production capacity to meet
future demand, with volume forecasts growing from 20,000 units annually to an estimated 50,000 units by 2027.
CGuard
EPS and CGuard Prime consist of a CGuard stent and the delivery system. Each CGuard stent is manufactured from two main components, a
self-expanding nickel-titanium stent and the PET polymer mesh. The mesh is made from polyethylene terephthalate (PET). We have patent
rights that cover the proposed CGuard stent with mesh. During 2022 our mesh supplier informed us that they will not be able to supply
the polymer fiber in the future due to supply issues with the current PET resin, therefore we purchased inventory which should be sufficient
to support our production needs until the end of 2027. We are currently testing a different source of PET showing equivalent mechanical
properties and biocompatibility of the original raw material. BioGeneral will produce the fiber from the new PET: some samples were already
produced with different PET resins for preliminary R&D testing. Once the new resin will be chosen, complete validation process will
take up to 18 months. The delivery system of CGuard consists of several sub-assemblies procured from original equipment manufacturers
and assembled in-house. In the event that one of our suppliers can no longer supply one of the components, we would need to qualify another
supplier, which could take up to a year depending on the component and its criticality. In addition, in order to retain the approval
of the CE mark, we are required to perform periodic audits of the quality control systems of our key suppliers in order to ensure that
their products meet our predetermined specifications.
Human
Capital Management
As
of December 31, 2024, we had 86 employees, 85 full-time and one part-time, consisting of six in executive management, six in research
and development, nine in quality assurance and compliance, seven in finance and accounting, 34 in operations/production, 14 in commercial
(including sales and marketing), three in clinical and seven in human resources, IT and administration. Except for four of our employees
in Europe, our employees are not party to any collective bargaining agreements. We do not expect the collective bargaining agreements
to which our employees are party to have a material effect on our business or results of operations. We also employ 1 independent contractor
in Brazil.
We
believe that our future success will depend, in part, on our continued ability to attract, hire and retain qualified personnel. In particular,
we depend on the skills, experience and performance of our senior management and research personnel. We compete for qualified personnel
with other medical device, biotechnology, pharmaceutical and healthcare companies, as well as universities and non-profit research institutions.
We
provide competitive compensation and benefits programs to help meet the needs of our employees. In addition to salaries, these programs
(which vary by country/region and employment classification) include incentive compensation plan, pension, healthcare and insurance benefits,
paid time off, family leave, and on-site services, among others. We also use targeted equity-based grants with vesting conditions to
facilitate retention of personnel, particularly for our key employees.
We
consider our relations with our employees to be good.
30