owners that operate within infrastructures that cannot be reasonably protected by traditional fire sprinklers.
−Removed: with Sparx Technologies, LLC (“Sparx”) to pioneer the fire protection industry with a commercially available wireless
−Removed: electronic fire sprinkler network and develop the industry’s first commercially available wireless electronic fire sprinkler
−Removed: system that can be adaptable for a variety of different applications and customers.
−Removed: 1 Traditional fire sprinklers are primarily mechanical
−Removed: devices that contain a heat-sensitive element that could be in the form of a glass bulb or a fusible metal link that will rupture or melt
−Removed: at a certain temperature threshold, activating the sprinkler and allowing water to flow.
−Removed: Traditional sprinklers will not turn on all at
+Added: Traditional fire
+Added: sprinklers are primarily mechanical devices that contain a heat-sensitive element that could be in the form of a glass bulb or a
+Added: fusible metal link that will rupture or melt at a certain temperature threshold, activating the sprinkler and allowing water to
+Added: Traditional sprinklers will not turn on all at once.
Each one activates independently, on its own.
+Added: We intend, with Sparx
+Added: Technologies, LLC (“Sparx”), to pioneer the fire protection industry with a commercially available wireless electronic
+Added: fire sprinkler network and develop the industry’s first commercially available wireless electronic fire sprinkler system that
+Added: can be adaptable for a variety of different applications and customers.
On August 29, 2022, we entered into and consummated a Patent License Agreement
38 unchanged sentences
circuit boards, benchtop test electrical assemblies with DC and AC power supplies, troubleshoot designs with multimeters, and create wiring
−Removed: The Company has now begun to finalize the advanced wireless sprinkler design
−Removed: and build a prototype to be utilized in wireless fire suppression technology.
−Removed: A prototype is in the development stage.
−Removed: A utility patent
−Removed: is anticipated to be filed upon by the end of this year.
+Added: The Company, via Sparx Technologies, LLC, has now begun to finalize a
+Added: battery-operated wireless electronic sprinkler network design and build a prototype to be utilized in wireless fire suppression
+Added: A prototype is in the development stages.
+Added: It is the Company’s intent, in the near future, to launch a website that
+Added: will include development updates regarding this process.
+Added: At this time, the website is in the beta stages and is believed to be
+Added: several months away from being made live for public viewing.
+Added: The website is being designed by our sole officer, Cassandra DeNunzio.
+Added: January 4, 2023, the Company issued 75,000 shares of our Common Stock to a non-related party in exchange for their services related to
+Added: designing a component of the battery-operated wireless electronic sprinkler network that is currently being developed by Sparx Technologies,
+Added: As mentioned previously, the battery-operated wireless electronic sprinkler network, remains in the prototype stages of development
+Added: On January 20, 2023, Sparx Technologies, LLC filed a utility patent
+Added: application with the USPTO under 35 USC 111(a) for a Mesh Network Fire Suppression System and Associated Methods with Serial No.
+Added: A prior provisional application with Serial No.
+Added: 63/304,302 was issued by the USPTO on January 28, 2022.
+Added: In addition, an
+Added: international patent application (PCT) was also filed with the USPTO on January 23, 2023, resulting in international patent pending
+Added: An international application Serial No.
+Added: PCT/US23/11314 was issued by the USPTO.
The Company plans to commercialize Licensor’s wireless fire suppression
technology into a fire protection/fire safety product line and seek approval from regulators.
−Removed: We plan to offer our advanced proprietary
−Removed: wireless sprinkler technology in the design, installation, and system integration to protect a variety of premises including commercial
−Removed: buildings and industrial sites from highly challenging fires.
−Removed: We believe that there is a lot of room for innovation and opportunity
−Removed: to meet the fire protection needs of today's modern businesses and building owners.
−Removed: The design of fire sprinklers has not changed significantly
−Removed: over the last fifty or so years and still consists of mostly simple mechanical components 1 .
−Removed: Traditional sprinklers cultivated
−Removed: from 19 th century science use the same physical element to detect fires as they do to cause water to flow.
−Removed: Because the heat-sensitive
−Removed: operating element of traditional fire sprinklers shares two important primary functions, this technology can face significant complications.
−Removed: If a fire starts near the ground under a storage rack in a tall warehouse, significant fire spread can occur by the time a fire is detected
−Removed: at the ceiling, where sprinklers are commonly located.
−Removed: Because detection and activation are combined functions of traditional sprinkler
−Removed: technology, a single sprinkler could operate and a phenomenon known as sprinkler skipping can occur that will cause sprinklers farther
−Removed: away from the fire origin to activate earlier than those that are closer and fire can continue to spread 2 .
−Removed: Our patented technology
−Removed: will allow for the decoupling of fire detection from sprinkler activation and will provide us with the ability to have greater control
−Removed: over sprinkler operations and respond to fires very early on in fire development.
−Removed: We believe that we can disrupt the fire sprinkler industry
−Removed: with our ability to leverage electronics and software in fire sprinkler system design by fundamentally changing the way the industry approaches
−Removed: fire suppression.
−Removed: We intend to create a framework for fire protection that will
−Removed: allow for wireless communication and electronic detection and actuation of sprinklers.
−Removed: With this framework, we will be able to use the
−Removed: same basic hardware components, and program application-specific algorithms 3 tailored to the building, environment, and the
−Removed: structure and commodities the system is designed to protect.
−Removed: Our framework will allow us to make minimal, non-invasive changes when applying
−Removed: our patented technology from one customer-specific application to the next, allowing us to formulate solutions for various HCFs quickly
−Removed: and effectively.
−Removed: Having the ability to pull additional levers with software and algorithms will give us the edge we need to deliver where
−Removed: traditional sprinklers cannot.
−Removed: We will be able to use software to change the way sprinklers respond to fires without redesigning the physical
−Removed: components of the sprinkler itself.
−Removed: This flexibility and adaptability will give Sparx an advantage when it comes to making design changes
−Removed: and expanding our product offerings.
+Added: We plan to offer our advanced
+Added: proprietary wireless sprinkler technology in the design, installation, and system integration to protect a variety of premises
+Added: including commercial buildings and industrial sites from highly challenging fires.
+Added: We believe that there is a lot of room for innovation and
+Added: opportunity to meet the fire protection needs of today's modern businesses and building owners.
+Added: The design of fire sprinklers has
+Added: not changed significantly over the last fifty or so years and still consists of mostly simple mechanical components 1 .
+Added: Traditional sprinklers cultivated from 19 th century science use the same physical element to detect fires as they do to
+Added: cause water to flow.
+Added: Because the heat-sensitive operating element of traditional fire sprinklers shares two important primary
+Added: functions, this technology can face significant complications.
+Added: If a fire starts near the ground under a storage rack in a tall
+Added: warehouse, significant fire spread can occur by the time a fire is detected at the ceiling, where sprinklers are commonly located.
+Added: Because detection and activation are combined functions of traditional sprinkler technology, a single sprinkler could operate and a
+Added: phenomenon known as sprinkler skipping can occur that will cause sprinklers farther away from the fire origin to activate earlier
+Added: than those that are closer and fire can continue to spread 2 .
+Added: Our patented technology in the product(s) we seek to offer,
+Added: will allow for the decoupling of fire detection from sprinkler activation and will provide us with the ability to have greater
+Added: control over sprinkler operations and respond to fires very early on in fire development.
+Added: We believe that we can disrupt the fire
+Added: sprinkler industry with our ability to leverage electronics and software in fire sprinkler system design by fundamentally changing
+Added: the way the industry approaches fire suppression.
+Added: Via Sparx Technologies, LLC, we intend to create a
+Added: framework for fire protection that will allow for wireless communication and electronic detection and actuation of sprinklers.
+Added: this framework, we will be able to use the same basic hardware components, and program application-specific algorithms 3
+Added: tailored to the building, environment, and the structure and commodities the system is designed to protect.
+Added: Our framework will allow
+Added: us to make minimal, non-invasive changes when applying our patented technology from one customer-specific application to the next,
+Added: allowing us to formulate solutions for various highly challenging fires quickly and effectively.
+Added: Having the ability to pull additional
+Added: levers with software and algorithms will give us the edge we need to deliver where traditional sprinklers cannot.
+Added: We will be able to
+Added: use software to change the way sprinklers respond to fires without redesigning the physical components of the sprinkler itself.
+Added: flexibility and adaptability will give Sparx an advantage when it comes to making design changes and expanding our product
“A History of Fire Sprinklers - IFSEC Global:
12 unchanged sentences
Liquidity and Capital Resources
−Removed: Our cash balance is $0 as of September 30,
+Added: Our cash balance is $0 as of December 31,
Our cash balance is not sufficient to fund our limited levels of operations for any period of time.
11 unchanged sentences
We have recorded a net loss of $2,054 for
−Removed: the three months ended September 30, 2022 and a net loss of $782 for the three months ended September 30, 2021.
+Added: the three months ended December 31, 2022 and a net loss of $16,829 for the six months ended December 31, 2022.
+Added: We have recorded a net loss of $1,850 for
+Added: the three months ended December 31, 2021 and a net loss of $2,632 for the six months ended December 31, 2021.
Until we are able to
18 unchanged sentences